A pressure gauge is the instrument that indicates the gauge pressure of a fluid on a graduated dial, almost always through a Bourdon tube that deforms under pressure and drives the pointer through an amplifying movement. Choosing well means deciding five things: measuring principle, dry or glycerin-filled case, materials, dial size with its connection, and accuracy class with the correct range.

Quick verdict: for compressed air, water and oils without vibration use a dry gauge with bronze internals; if there is machine vibration or pump/compressor pulsation, use a glycerin-filled gauge or a dry gauge with an internally dampened movement; for chemicals or corrosive environments, all-stainless-steel case and internals (plus a diaphragm seal if the fluid attacks stainless or clogs); for steam, any gauge always with a siphon; and for very low gas pressures (water-column ranges), a capsule gauge, not a Bourdon.

How it works: Bourdon, diaphragm and capsule

The classic element is the Bourdon tube: a metal tube of flattened cross-section bent into a C shape that tends to straighten as internal pressure rises. That tip travel — a few millimeters — is amplified by a sector-and-pinion movement that rotates the pointer. For high ranges the tube is made spiral or helical. The European standard for these instruments, EN 837-1, covers nominal sizes from 40 to 250 mm and ranges up to 1,600 bar (23,200 psi).

Below roughly 1 bar the Bourdon loses sensitivity, and the elements of the standard EN 837-3 take over: the diaphragm (also suited to dirty or viscous fluids) and the capsule (two membranes welded at the rim), the standard choice for gas in millibar or inches of water. That case is covered by the 2.5 in gauge in inches of H₂O in the TECTUL catalog.

Dry, glycerin-filled or dry-dampened: when to use each

The difference is not quality but service. A dry gauge has an air-filled case; it is more economical, reads without distortion and accepts any ambient temperature within the instrument's rating. A glycerin-filled gauge has the case filled with glycerin (typically 99.7 %): the liquid damps the pointer, lubricates the movement and absorbs vibration and pressure surges.

There is a third, modern option: the gauge with a dry-dampened movement, an internally dampened mechanism that stops pointer flutter without liquid in the case (Winters markets it, for example, as StabiliZR), with vibration and pulsation performance comparable to a glycerin fill per the manufacturer's testing. Its advantage shows up over the years: glycerin yellows or darkens with UV rays and above about 65 °C (150 °F) — per Ashcroft documentation — until the dial becomes hard to read; the dry-dampened movement delivers the same stability without that aging, with no fill fluid to leak and no draining of the case to service the instrument.

CriterionDryGlycerin-filledDry-dampened
Machine vibration (pumps, compressors, chassis)The pointer flutters and the movement wears prematurelyThe pointer stays steady and the fill lubricates the movementThe pointer stays steady: the dampened movement stops flutter without liquid
Fluid pulsation (positive displacement)Unreadable pointer; requires an external dampenerDamps the reading; under severe pulsation a restrictor or snubber is added as wellComparable to glycerin fill; restrictor under severe pulsation
Ambient temperatureThat of the instrumentGlycerin: −20 to +60 °C (−4 to +140 °F); outside that range, a silicone fill (down to −40 °C) per WIKAThat of the instrument: not bound by the limits of a fill liquid
Long-term readabilityStable dialGlycerin yellows or darkens with UV and temperature until the dial becomes hard to readNo liquid to yellow: the window stays clear
Humid or condensing environmentsMay fog internallyThe fill prevents internal condensation on the windowMay fog like any dry case; a sealed case mitigates it
Maintenance and leaksNo liquidPossible fill leakage; draining and refilling needed for serviceNo liquid to leak or refill
CostLowerHigher (fill and sealed case)Higher than a conventional dry gauge

Practical rule: if the gauge mounts on or near rotating equipment, or measures the discharge of a pump or compressor, order glycerin-filled or dry-dampened (prefer dry-dampened when the dial must remain readable for years outdoors or near heat); at a static point of the network, a dry gauge does the job at lower cost. Compare: 2.5 in black-case dry gauge and 2.5 in stainless-case glycerin-filled gauge.

Materials: case and internals by fluid and environment

Two separate decisions: the case is chosen by the environment (outdoors, washdowns, corrosive atmosphere) and the wetted parts are chosen by the fluid that enters the instrument.

ConfigurationCaseWetted partsTypical service
Black case + bronzeBlack-painted carbon steelCopper alloy (bronze/brass)Compressed air, water, oils and non-corrosive fluids in dry indoor areas; the most economical option
Stainless case + bronze304 stainless steelCopper alloyNon-corrosive fluid in a demanding environment: outdoors, humidity, frequent washdowns
All stainless304 stainless steel316 stainless steelChemicals compatible with 316, steam and ammonia (which attacks copper alloys)
All stainless + diaphragm sealStainless steelThe fluid only touches the seal's diaphragmFluids that corrode even 316, crystallize, polymerize or clog (slurries, resins, hot acids)

The chemistry rule is direct: bronze for neutral fluids; 316 stainless when in doubt or with corrosion; diaphragm seal when even 316 is not enough or when the fluid would clog the Bourdon's capillary. For the all-stainless line, the catalog reference is the 4 in all-stainless gauge with recalibratable pointer, which allows adjusting zero against a reference without opening the movement.

Dial size: readability and accuracy go together

Commercial dials run from 1.5 to 4 in (equivalent to the 40, 50, 63 and 100 mm nominal sizes of EN 837-1); 6 in (160 mm) dials are used on boiler panels. A larger dial accepts finer graduations and better accuracy classes; a 1.5 in dial cannot carry the graduations a high class would require.

Connections: NPT size and position

In Colombia the dominant thread is the tapered NPT per ASME B1.20.1. Connection size follows the dial: 1.5-2 in → 1/8 in NPT; 2.5 in → 1/4 in NPT; 4 in and larger → 1/2 in NPT — the matrix of the TECTUL catalog.

Accessories: on steam, a siphon (pigtail) keeps a condensate plug between live steam and the Bourdon; under severe pulsation, a restrictor; and to remove the instrument without shutting the line, an isolation-and-bleed gauge valve. All standardized in ASME B40.100.

Accuracy classes: ASME B40.100 and EN 837-1

Accuracy is expressed as ± % of span. The American standard ASME B40.100-2022 defines grades; in grades A through D the permitted error changes by dial zones (lower quarter - middle half - upper quarter). The European standard EN 837-1 defines classes with a single value over the full span.

ASME B40.100 gradeError (± % of span)Comparable EN 837-1 classTypical use
4A0.10.1Laboratory reference standards
3A0.250.25Test and calibration gauges
2A0.50.6Accuracy-demanding process (4 in dials and larger)
1A11General industrial process
A2 - 1 - 2 (by zones)1.6Standard plant monitoring
B3 - 2 - 3 (by zones)2.5General indication on 1.5 to 2.5 in dials
C4 - 3 - 4 (by zones)4Basic indication
D5 - 5 - 5Visual reference only

Practical reading: a commercial 2.5 in gauge is usually grade B or class 1.6/2.5. If the reading feeds quality control or a report, specify grade 1A/class 1 or better on a 4 in dial, and verify the class marked on the dial face.

Range selection rule

The Bourdon works best away from its extremes: the correct range is not the one that just reaches your pressure. The practice recommended by manufacturers in line with ASME B40.100:

  1. Choose a range close to twice the operating pressure, so the pointer works in the middle third of the dial (normal pressure sits near 12 o'clock).
  2. In steady service, operating pressure should fall between 25 and 75 % of full scale.
  3. With pulsation, maximum operating pressure should not exceed 50 % of full scale.
  4. Check the peaks: water hammer and start-ups must stay within the range; if not, protect the instrument with a snubber or an overpressure limiter.

Example: compressed-air network at 100 psi (6.9 bar) → 0-200 psi gauge (0-14 bar), not 0-100 psi.

Selection table by application

ApplicationRecommended configurationMandatory accessory
Compressed air and pneumaticsDry, black or stainless case, bronze internals, 2.5 in, 1/4 in NPTNone; glycerin-filled if mounted on the compressor
Water and pumpingGlycerin-filled or dry-dampened at pump discharge (pulsation); dry at static pointsIsolation valve for maintenance
SteamAll stainless (316 internals), drySiphon always; glycerin fill is not recommended due to temperature
ChemicalsAll stainless 316; with diaphragm seal if the fluid corrodes, crystallizes or clogsDiaphragm seal with a compatible fill fluid
Low-pressure gas (burners, internal networks)Capsule gauge with scale in mbar or inches of H₂ONone; verify gas compatibility with bronze
Vibrating equipment (chassis, presses)Glycerin-filled or dry-dampened; back connection if read on a panelRestrictor under severe pulsation

Practical purchasing recommendation

To quote a pressure gauge, five data points are enough: fluid, operating pressure (the range will be twice that value), vibration or pulsation (defines dry, glycerin-filled or dry-dampened), dial size and connection (bottom to the line, back to a panel) and the accuracy class if the reading feeds quality or control. The TECTUL catalog covers the full matrix: 2.5 in black-case dry gauge for general services, compact 1.5 in back-connection gauge for panels, 2.5 in stainless-case glycerin-filled gauge for vibration, 4 in all-stainless recalibratable gauge for process and chemicals, and a capsule gauge in inches of H₂O for low-pressure gas. Ranges, dual psi/bar scales and accessories (siphons, gauge valves, seals) are quoted via WhatsApp with the data of the measurement point.