Solvent-Weld PVC Pressure Cap is a product in the pipe fittings family for fluid conduction in PVC. 10 sizes published with per-variant price and availability. Weld connection. Price from $ 500 COP before VAT.

| SKU | Size | Unit price (from) | Availability | Qty | |
|---|---|---|---|---|---|
| VT-58583-01 | 1/2" | $ 500 | In stock | ||
| VT-58583-02 | 3/4" | $ 500 | In stock | ||
| VT-58583-03 | 1" | $ 500 | In stock | ||
| VT-58583-04 | 1-1/4" | $ 500 | In stock | ||
| VT-58583-05 | 1-1/2" | $ 500 | In stock | ||
| VT-58583-06 | 2" | $ 500 | In stock | ||
| VT-58583-07 | 2-1/2" | $ 500 | In stock | ||
| VT-58583-08 | 3" | $ 500 | In stock | ||
| VT-58583-09 | 4" | $ 500 | In stock | ||
| VT-58583-10 | 6" (Bajo pedido) | $ 500 | Made to order |
Prices per size, per unit, before VAT. Confirmed in the quote together with shipping.
| Family | Pipe fittings |
| Material | Pvc |
| Connection | Weld |
| Sales unit | Se vende por Unidades (Unid.) |
| Availability | In stock |
| Factory PDF data sheet | Available from an advisor |
The solvent-weld PVC pressure cap closes the end of a PVC pressure pipe with a solvent-cemented socket, leaving a permanent closure. It belongs to the PVC pressure system: pipe per NTC 382, Schedule 40 fittings per NTC 1339 (antecedent ASTM D2466-24) and solvent cement per NTC 576. The lot covers 1/2" to 6", with 6" made to order.
| Feature | Specification |
|---|---|
| Fittings standard | NTC 1339 — Schedule 40 PVC pressure fittings; antecedent ASTM D2466-24. Product seal of the lot confirmed when quoting |
| System pipe standard | NTC 382 — PVC pressure pipe classified by RDE (SDR) |
| Joint | Socket solvent-cemented per NTC 576; permanent, non-demountable closure |
| Service | End closure in pressurized water networks; working pressure is set by the pipe RDE and diameter — confirm when quoting |
| Material | Rigid PVC |
| Lot sizes | 1/2", 3/4", 1", 1-1/4", 1-1/2", 2", 2-1/2", 3", 4", 6" (6" made to order) |
Before using these data in engineering decisions — design, installation or systems with mechanical risk of pressure, rupture, fatigue, impact or water hammer — you must read the Technical notice and limitation of liability at the end of this page.
We dispatch to Bogotá, Medellín, Cali, Barranquilla and all of Colombia. Quote the solvent-weld PVC pressure cap via WhatsApp stating size and quantity to confirm availability.
Schedule 40 PVC pressure fittings follow NTC 1339, whose antecedent is ASTM D2466-24; the solvent cement follows NTC 576 and the pipe NTC 382. The product seal of the lot is confirmed when quoting.
The solvent-weld cap stays cemented per NTC 576 as a permanent closure; the threaded one can be removed for inspection or future line extension.
No single pressure is published: the working pressure of the point is defined by the pipe RDE per NTC 382 and the diameter, and is confirmed per reference when quoting.
With solvent cementing per NTC 576: square cut, bevel, primer, uniform cement and full insertion, holding the part still during initial set and respecting the cure before pressurizing.
Before using these data in engineering decisions — design, installation or systems with mechanical risk of pressure, rupture, fatigue, impact or water hammer — you must read the Technical notice and limitation of liability at the end of this page.
Carbon Steel SCH 40 Butt-Weld Elbow✔️economical
Rigid Grooved Coupling
Stainless Steel Threaded Elbow
Stainless Steel Threaded Union
Stainless Steel Wall Sleeve with Threaded EndsUpdated: July 22, 2026
The dimensions, thicknesses, pressures, temperatures and other characteristics stated in this data sheet are theoretical nominal reference values, compiled from publicly available technical sources: international standards (ASME, ASTM, API, MSS, ISO and NTC, depending on the product) and published engineering literature. They are average approximations intended to guide selection, not a certificate of conformity for any given lot.
Actual values may vary due to conditions inherent to the manufacturing process — dimensional and wall-thickness tolerances (in pipe, typically ±12.5%), surface finish and residual stresses from forming or welding — and to factors inherent to the raw material — chemical composition variations within the ranges allowed by the standard, inclusions or heat-to-heat differences. They may also be affected by in-service events not foreseeable at design time: water hammer, vibration, thermal and mechanical fatigue, corrosion and operating overpressures, which can cause the element to fail before its estimated service life.
To know the certified behavior of a specific lot, TECTUL supplies upon request the manufacturer's mill test certificate (MTC) issued per the product standard; for critical applications, laboratory testing of the lot can also be arranged. In the absence of such certification, the data provided here must not be used as the sole criterion in critical or safety applications, or wherever the integrity of the line may compromise the lives of people or property; in such cases, consult our technical team first.