TECTUL · Dispatch across Colombia · Exports to Central & South America
Smooth-inner-wall flexible duct for HVAC, air extraction and ventilation systems in commercial and industrial buildings. Covers 4″ to 50″ (100 to 1270 mm inner diameter), in 10 m rolls. Working temperature range -20 °C to +80 °C. Corrosion- and weather-resistant for outdoor use, with high flexibility for installation in tight spaces. It is a low-pressure air-conveyance product, not for liquid fluids or high-temperature service; the catalog's fiberglass, polyester and silicone ducts cover that higher thermal range on separate sheets.

IMPORTANT: reference data — may differ from the physical product; verify with an advisor before buying.
VT-142172 · Flexible duct, sold in 10 m rolls
| Nominal diameter NPS [in] | Inner diameter mm |
|---|---|
| 4″ | 100 |
| 5″ | 125 |
| 6″ | 150 |
| 8″ | 200 |
| 10″ | 250 |
| 12″ | 300 |
| 14″ | 350 |
| 16″ | 400 |
| 18″ | 450 |
| 24″ | 600 |
| 28″ | 700 |
| 32″ | 800 |
| 38″ | 915 |
| 40″ | 1000 |
| 42″ | 1067 |
| 48″ | 1200 |
| 50″ | 1270 |
| Parameter | Value |
|---|---|
| Inner wall | Smooth, for efficient airflow and minimal pressure loss |
| Working temperature | -20 °C to +80 °C (-4 °F to +176 °F) |
| Resistance | Corrosion and weather resistant, suitable for outdoor use |
| Presentation | 10 m rolls |
IMPORTANT
This technical data sheet is a reference guide to the properties of this product type; it is not a quality certificate for the product you are buying. The measurements, dimensions and physical or geometric characteristics of the product supplied may vary by manufacturer, heat and lot, and may even fall outside the cited standards. If any of these figures is critical to your design or build, verify it with one of our advisors against the physical product or the lot's mill certificate, so you can be fully certain of what you are buying. · Original data sheet: tectul.com/en/conduccion-de-fluidos/mangueras/ficha-tecnica-ducto-flexible.html
This flexible duct covers the general HVAC and ventilation temperature range (-20 °C to +80 °C): air conditioning, bathroom and kitchen air extraction, and ventilation of commercial and industrial spaces. It is not designed for hot process-gas extraction or ovens: for those services, the catalog has dedicated fiberglass duct, polyester duct and silicone duct sheets, formulated for much higher temperatures. Confirm the actual temperature of the air or gas to be conveyed before choosing this reference.
With diameters from 4″ to 50″ (100 to 1270 mm), it covers everything from single bathroom extraction points to main building HVAC ducts; the table's inner diameter is the selection criterion against the equipment (grille, extractor, air handling unit) to be connected.
No: its upper limit is 80 °C. For hot process gases use the catalog's fiberglass, polyester or silicone duct sheets, formulated for high temperature.
Yes, it is corrosion and weather resistant, per the manufacturer sheet.
From 4″ to 50″ (100 to 1270 mm inner diameter), in 10-meter rolls, per the technical data table.
Confirm the actual temperature of the air/gas to be conveyed: above 80 °C use a high-temperature duct from the catalog.
Avoid very tight bend radii; the smooth inner wall only reduces pressure loss if the duct is extended, not compressed accordion-style.
Select diameter by required airflow and equipment connection, not only by the existing duct's nominal size.
The pressures, dimensions, weights and other characteristics in this sheet are theoretical calculation values obtained from nominal properties published in the standards cited (ASME B36.10-2022, ASME B31.3-2024, ASTM A106/A106M-19a, ASTM A53/A53M-24, API Spec 5L 46th ed.). They guide selection; they are not a certificate of conformity for any given lot.
The actual behavior of each lot varies with manufacturing — wall tolerance (up to −12.5%), out-of-roundness, residual stresses — and with the raw material — chemical composition within the ranges the standard allows, heat-to-heat differences. To certify a lot, the tests defined by its product standard are required: tensile test, flattening test and hydrostatic test, documented in the manufacturer's mill test certificate (MTC), which TECTUL supplies upon request; testing of the lot in an independent laboratory can also be arranged.
These values must not be used as the sole criterion in critical or safety applications, or wherever failure of the line may compromise people, property or the environment: in such cases the design belongs to the project's responsible engineer under the applicable code (ASME B31.3, B31.1 or the one governing the installation), with the design temperature, corrosion allowance and load cases of the actual service. Before deciding with these data, consult our technical team.
This data sheet is the property of TECTUL, part of the Industrias IMR group. Reproduction without attribution is prohibited. Original document and updates: tectul.com/en/conduccion-de-fluidos/mangueras/ficha-tecnica-ducto-flexible.