← Product page Quote via WhatsApp
TECTULby IMR
Fittings and couplings · Camlock couplings
TECHNICAL DATA SHEET
FT-TC-RAC-CAMLOCK-INOXIDABLE-001
Issue date: August 5, 2026 · Rev. 001
Check the current version

Stainless steel 304 camlock couplings — parts A, B, C, D, E, F and dust cap

TECTUL · Dispatch across Colombia · Exports to Central & South America

Camlock is a two-lug quick-connect coupling system that connects and disconnects tool-free in seconds, standardized under US federal standard A-A-59326D (successor to MIL-C-27487, replaced in 1998) to guarantee interchangeability between manufacturers. In stainless steel 304, it is used where aluminum cannot withstand the fluid (chemicals, food, pharmaceutical, potable water, corrosive or marine environments). The TECTUL stainless catalog covers parts A (male camlock x female thread, confirmed 1/2″ to 4″ range), B (female camlock x male thread), C (female camlock x hose shank), D (female camlock x female thread), E (male camlock x hose shank) and F (male camlock x male thread), plus the protective dust cap.

Stainless steel 304 camlock couplings — parts A, B, C, D, E, F and dust cap
Interchangeability standard
A-A-59326D (formerly MIL-C-27487, replaced in 1998)
confirmed in the TECTUL catalog's Part A product sheet
Confirmed dimensional range (Part A)
1/2″ to 4″
range of the other parts confirmed on quotation
Pressure rating (industry reference)
150 psi (1/2″) · 250 psi (3/4″–2″) · 75–225 psi (2-1/2″+)
typical for 316 stainless; confirm the exact 304 stainless rating with the supplier
Material
Stainless steel 304 (Part A confirmed; rest of the catalog with no individually published grade)
for potable water, food, compatible chemicals and corrosive environments

Important: Before using these data in engineering, design or installation decisions on systems exposed to mechanical, pressure, rupture, fatigue, impact or water-hammer risk, it is essential to read the technical notice and limitation of liability at the end of this sheet.

Parts A–F and dust cap in stainless steel 304 · 1/2″–4″ (Part A confirmed) · sold by the unit

1. Technical specifications

Camlock system part identification

PartConfigurationTypical function
AMale camlock adapter x female threadConnect a hose with a D coupler to piping with male thread
BFemale camlock coupler (with lugs) x male threadConnect to a tank or piping with female thread
CFemale camlock coupler (with lugs) x hose shankTerminate a hose in a female lugged end
DFemale camlock coupler (with lugs) x female threadConnect to male-threaded piping via an A adapter
EMale camlock adapter x hose shankTerminate a hose in a male end
FMale camlock adapter x male threadConnect to a female coupler with female thread or a tank
Dust cap (DC)Female protector with lugs, no flow pathClose a male adapter when not in use

Dimensional range and rating

Part A1/2″ to 4″ — confirmed in the TECTUL catalog's product sheet
Parts B, C, D, E, F, dust capExact range not individually confirmed — confirmed on quotation
MaterialStainless steel 304 (Part A) — grade of the other parts confirmed on quotation
Industry reference pressure rating150 psi at 1/2″ · 250 psi from 3/4″ to 2″ · 75–225 psi from 2-1/2″ up (typical 316 stainless values from industry catalogs; the specific 304 rating is confirmed with the supplier)
StandardA-A-59326D (US Federal), successor to MIL-C-27487 — interchangeability confirmed in the product sheet

Stainless steel 304 resists water, food and many neutral chemicals well, but is less resistant than 316 to chlorides (seawater, some chlorinated cleaners); if service includes sustained chloride exposure, confirm with the supplier whether a 316 reference exists.

2. Frequently asked questions

Why choose stainless over aluminum?

When the fluid corrodes aluminum (acids, some bases, sustained free chlorine) or when the application demands hygiene (food, potable water, pharmaceutical) or resistance to a marine/corrosive environment.

Is 304 suitable for seawater?

For occasional exposure yes, but for immersion or sustained seawater spray, 316 (with molybdenum) resists chlorides better. Confirm with the supplier whether the catalog offers a 316 version.

Are all catalog parts stainless 304?

Grade 304 is confirmed for Part A in the current product sheet; for the other parts (B, C, D, E, F, dust cap) the exact grade is not individually published and is confirmed on quotation.

3. Application notes

Feasibility

Stainless steel 304 is the camlock system option for potable water, food, pharmaceutical, compatible chemicals and corrosive environments where aluminum cannot withstand. For sustained chlorides (seawater, some chlorinated cleaners), confirm whether 316 is required.

Installation

Insert the male end into the female one fully and close both lugs until they lock; no tool is required. Verify the internal gasket is present, intact, and compatible with the fluid (EPDM, Viton or other depending on service). To disconnect, lift both lugs simultaneously.

Design

Confirm the exact dimensional range of each part other than A, the stainless steel grade if critical (304 vs. 316), and the certified lot pressure rating with the supplier before specifying on a critical line.

4. Technical notice and limitation of liability

The pressures, dimensions, weights and other characteristics in this sheet are theoretical calculation values obtained from nominal properties published in the standards cited (ASME B36.10-2022, ASME B31.3-2024, ASTM A106/A106M-19a, ASTM A53/A53M-24, API Spec 5L 46th ed.). They guide selection; they are not a certificate of conformity for any given lot.

The actual behavior of each lot varies with manufacturing — wall tolerance (up to −12.5%), out-of-roundness, residual stresses — and with the raw material — chemical composition within the ranges the standard allows, heat-to-heat differences. To certify a lot, the tests defined by its product standard are required: tensile test, flattening test and hydrostatic test, documented in the manufacturer's mill test certificate (MTC), which TECTUL supplies upon request; testing of the lot in an independent laboratory can also be arranged.

These values must not be used as the sole criterion in critical or safety applications, or wherever failure of the line may compromise people, property or the environment: in such cases the design belongs to the project's responsible engineer under the applicable code (ASME B31.3, B31.1 or the one governing the installation), with the design temperature, corrosion allowance and load cases of the actual service. Before deciding with these data, consult our technical team.

Sources

This data sheet is the property of TECTUL, part of the Industrias IMR group. Reproduction without attribution is prohibited. Original document and updates: tectul.com/en/conduccion-de-fluidos/racores-y-acoples/ficha-tecnica-parte-a-inoxidable.

Check the current version
TECTUL · FT-TC-RAC-CAMLOCK-INOXIDABLE-001 · Rev. 001 · August 5, 2026WhatsApp +573161111666