Fire Hose Cabinet is a product in the fire protection systems family for fluid conduction in lámina CR pintada, NTC 1669 / NFPA 14. Available made to order, quoted via WhatsApp. Supplied on request.

| Family | Fire protection systems |
| Material | Lámina cr pintada |
| Standard | NTC 1669 / NFPA 14 |
| Connection | Other |
| Sales unit | Se vende por Unidades (Unid.) |
| Availability | Made to order |
The fire hose cabinet gathers in a visible station the initial attack or internal support elements of a hydraulic network: painted CR sheet metal cabinet, hose, valve, nozzle and accessories according to the project configuration. It is specified with reference to NTC 1669 and NFPA 14 for hose and standpipe systems, always within the design approved by the fire protection manager. Unlike a fire department connection, which serves as an exterior connection for firefighters, the cabinet is a point of use inside the building or industrial area. Its selection must consider system class, location, hose type, angle valve, nozzle, signage, available depth and finish. A useful cabinet is not just a box: it must allow fast access, easy inspection and component replacement.
We dispatch to Bogotá, Medellín, Cali, Barranquilla and all of Colombia. Request a quote via WhatsApp for your fire hose cabinet indicating configuration, quantity and city.
It depends on internal configuration, cabinet type, finish, hose, valve, nozzle and quantity. TECTUL quotes by project.
The cabinet is an internal point with a hose for use in the building. The fire department connection is an exterior connection to supply the network from firefighters.
It must be installed according to approved drawings, with height, access, signage, hydraulic connection and internal components defined by the design.
For cabinets and hose systems, NTC 1669 and NFPA 14 are reviewed, in addition to local project requirements.
It may include hose, angle valve, nozzle, support, wrench and signage, according to the configuration requested in the quote.
Cabinet type, internal components, quantity, city, installation location and technical specification or drawing if available.
Before using these data in engineering decisions — design, installation or systems with mechanical risk of pressure, rupture, fatigue, impact or water hammer — you must read the Technical notice and limitation of liability at the end of this page.
Grooved Mechanical Tee
Low-Temperature Upright Fire Sprinkler
High-Temperature Upright Fire Sprinkler
High Temperature Pendent Fire Sprinkler
Low Response Pendent Fire SprinklerUpdated: July 22, 2026
The dimensions, thicknesses, pressures, temperatures and other characteristics stated in this data sheet are theoretical nominal reference values, compiled from publicly available technical sources: international standards (ASME, ASTM, API, MSS, ISO and NTC, depending on the product) and published engineering literature. They are average approximations intended to guide selection, not a certificate of conformity for any given lot.
Actual values may vary due to conditions inherent to the manufacturing process — dimensional and wall-thickness tolerances (in pipe, typically ±12.5%), surface finish and residual stresses from forming or welding — and to factors inherent to the raw material — chemical composition variations within the ranges allowed by the standard, inclusions or heat-to-heat differences. They may also be affected by in-service events not foreseeable at design time: water hammer, vibration, thermal and mechanical fatigue, corrosion and operating overpressures, which can cause the element to fail before its estimated service life.
To know the certified behavior of a specific lot, TECTUL supplies upon request the manufacturer's mill test certificate (MTC) issued per the product standard; for critical applications, laboratory testing of the lot can also be arranged. In the absence of such certification, the data provided here must not be used as the sole criterion in critical or safety applications, or wherever the integrity of the line may compromise the lives of people or property; in such cases, consult our technical team first.