TECTULby IMR
HomeIndustrial electricalIndustrial lightingIndustrial Vapor-Tight Luminaire

Industrial Vapor-Tight Luminaire

IP65 vapor-tight LED luminaire for dust and moisture areas: basements, machine rooms, process areas and parking garages.

Availability
Quote
Family
Industrial lighting
Line
Industrial
Response
Same business day
Industrial Vapor-Tight Luminaire
Product quoted on request

Tell us the reference or key specification (current, power, gauge, size), quantity and city — a technical advisor sends your quote the same business day.

01Technical description

The vapor-tight LED luminaire carries IP65 per IEC 60529 — dust-tight and protected against water jets — and typical IK08 impact resistance (5 joules per IEC 62262), for dusty, damp or washdown areas: machine rooms, basements, process areas and parking decks. Built to IEC 60598-1.

Industrial Vapor-Tight LED Luminaire is an enclosed luminaire for areas where lighting must be protected from dust, ambient moisture, indirect splashing or operational dirt. In the TECTUL lot it is reported as an IP65 vapor-tight LED luminaire for basements, machine rooms, process areas and parking garages. Its main difference from an LED area floodlight is the linear or enclosed format for routes, corridors and indoor areas; compared with an industrial LED highbay, it is not oriented to suspension from great height but to mounting on a low ceiling, slab, wall or structure near the circulation area. It is a practical option for industrial maintenance because it protects the optical and electrical assembly against environments more demanding than an open luminaire. To quote accurately, report required length or format, quantity, voltage, fastening type, moisture exposure level and whether it replaces existing tubes or luminaires.

Selection guide

  • Use IP65 when the environment has dust, moisture or indirect splashing; validate additional protection if there will be direct washdown or chemicals.
  • Define whether it will be installed on ceiling, wall, channel, metal structure or over tray to choose clips and fastening.
  • Confirm whether the application is parking garage, technical room, corridor, process area or basement to select distribution and quantity.
  • When replacing equipment, send a photo of the existing luminaire and connection point to validate compatible format.

Installation recommendations

  • Fasten the luminaire with firm clips or supports and avoid perforations that compromise the body seal.
  • Seal the cable entry properly; a poorly installed gland or gasket reduces the assembly protection.
  • De-energize the circuit before opening, connecting or removing the luminaire, and verify grounding/earthing when applicable.
  • Place it away from points where it may be hit by forklifts, piping, doors or moving equipment.

We dispatch to Bogotá, Medellín, Cali, Barranquilla and all of Colombia. Request a quote via WhatsApp for your industrial vapor-tight luminaire indicating quantity, format, voltage, installation site and work environment.

IK impact ratings (IEC 62262)

RatingImpact energyEquivalent
IK072 J0.5 kg mass from 40 cm
IK085 J1.7 kg mass from 29.5 cm
IK0910 J5 kg mass from 20 cm
IK1020 J5 kg mass from 40 cm

Impact classification per IEC 62262; the IP65 seal is declared under IEC 60529. IP65 + IK08 is the usual vapor-tight specification for process areas with equipment traffic.

02Frequently asked questions

What is the price of an industrial vapor-tight LED luminaire?

The price depends on format, quantity, availability, voltage and environmental conditions. TECTUL quotes via WhatsApp with the project data.

How does it differ from an LED area floodlight?

The industrial vapor-tight LED luminaire is enclosed and used in corridors, parking garages, basements or technical rooms. The LED area floodlight projects light toward yards, facades or outdoor areas.

How is an industrial vapor-tight luminaire installed or mounted?

It is fixed to ceiling, wall or structure with compatible clips or supports, connected to a protected circuit and the cable entry seal is protected.

What does IP65 mean in this luminaire?

IP65 indicates protection against dust and water ingress under controlled conditions. The installation must keep seals, cable glands and closures in good condition.

Where is it normally used?

It is used in basements, machine rooms, parking garages, process areas, technical corridors and indoor areas with ambient moisture or dust.

Does TECTUL dispatch vapor-tight luminaires to other cities?

Yes. TECTUL dispatches to Bogotá, Medellín, Cali, Barranquilla and other Colombian cities according to availability and carrier.

Where is an IP65 luminaire required?

In areas with airborne dust, condensation, splashes or periodic washdown: process areas, pump rooms, basements and parking decks — the IP65 seal (IEC 60529) keeps dust and water jets out of the fixture.

What does IK08 mean on a luminaire?

Resistance to a 5-joule impact per IEC 62262, equivalent to a 1.7 kg mass dropped from 29.5 cm: it protects the diffuser from accidental knocks by tools or moving loads.

03Related products

Need another electrical reference? We carry the full industrial lines of the catalogs we distribute — if the equipment or material you need is not published, we quote it anyway. Quote via WhatsApp

Updated: July 22, 2026