Rigid Copper Tube Type L is a product in the pipe & tubing family for fluid conduction in copper. 13 sizes published with per-variant price and availability. Price from $ 192.308 COP before VAT.

| SKU | Size | Unit price (from) | Availability | Qty | |
|---|---|---|---|---|---|
| VT-156440-01 | 1/4", Real: 3/8mm | Request a quote | Made to order | ||
| VT-156440-02 | 3/8", Real: 1/2mm | $ 192.308 | In stock | ||
| VT-156440-03 | 1/2", Real: 5/8mm | $ 269.231 | In stock | ||
| VT-156440-04 | 5/8", Real: 3/4mm | Request a quote | Made to order | ||
| VT-156440-05 | 3/4", Real: 7/8mm | $ 384.615 | In stock | ||
| VT-156440-06 | 1", Real: 1-1/8mm | $ 600.000 | In stock | ||
| VT-156440-07 | 1-1/4", Real: 1-3/8mm | $ 830.769 | In stock | ||
| VT-156440-08 | 1-1/2", Real: 1-5/8mm | $ 1.061.538 | In stock | ||
| VT-156440-09 | 2", Real: 2-1/8mm | $ 1.646.154 | In stock | ||
| VT-156440-10 | 2-1/2", Real: 2-5/8mm | $ 2.553.846 | In stock | ||
| VT-156440-11 | 3", Real: 3-1/8mm | $ 3.507.692 | In stock | ||
| VT-156440-12 | 4", Real: 4-1/8mm | Request a quote | Made to order | ||
| VT-156440-13 | 6", Real: 6-1/8mm | Request a quote | Made to order |
Prices per size, per unit, before VAT. Confirmed in the quote together with shipping. Sizes marked with * show the base reference price.
| Family | Pipe & tubing |
| Material | Cobre |
| Connection | Other |
| Sales unit | 6 metros |
| Availability | In stock |
| Factory PDF data sheet | Available from an advisor |
Rigid Type L copper tube is seamless copper tubing for installations where a balance between thickness, cost and performance is sought. ASTM B88/B88M covers copper water tubes in types K, L and M; Type L sits between K and M in wall thickness, so it is usually selected when Type M is not enough and Type K is oversized for the project. Nominal CTS sizes are not equal to the actual outside diameter, so it is advisable to quote with the nominal size and the actual size indicated in the sheet.
| Nominal size | Actual reported size | Presentation |
|---|---|---|
| 1/4" | 3/8mm | 6 meters |
| 3/8" | 1/2mm | 6 meters |
| 1/2" | 5/8mm | 6 meters |
| 5/8" | 3/4mm | 6 meters |
| 3/4" | 7/8mm | 6 meters |
| 1" | 1-1/8mm | 6 meters |
| 1-1/4" | 1-3/8mm | 6 meters |
| 1-1/2" | 1-5/8mm | 6 meters |
| 2" | 2-1/8mm | 6 meters |
| 2-1/2" | 2-5/8mm | 6 meters |
| 3" | 3-1/8mm | 6 meters |
| 4" | 4-1/8mm | 6 meters |
| 6" | 6-1/8mm | 6 meters |
Before using these data in engineering decisions — design, installation or systems with mechanical risk of pressure, rupture, fatigue, impact or water hammer — you must read the Technical notice and limitation of liability at the end of this page.
We dispatch to Bogotá, Medellín, Cali, Barranquilla and all of Colombia. Request a quote via WhatsApp for Type L copper tube with nominal size, number of lengths and intended application.
It depends on size, quantity and copper availability. TECTUL quotes per 6-meter length and can support fitting selection.
Type K has a thicker wall; Type L is intermediate and is used when the design does not require the heaviest wall.
It is installed with compatible soldering, brazing, compression or press fittings, depending on the network and fluid.
No. In CTS copper, the nominal size is not the outside diameter; that is why the table shows the actual reported size.
It may be used if the local standard, design and fittings allow it. Compatibility must be validated before installation.
Yes. TECTUL coordinates dispatches to Medellín, Cali, Barranquilla and all of Colombia.
Before using these data in engineering decisions — design, installation or systems with mechanical risk of pressure, rupture, fatigue, impact or water hammer — you must read the Technical notice and limitation of liability at the end of this page.
Seamless Schedule 40 Carbon Steel Pipe
Schedule 10 Carbon Steel Pipe
Heavy Type Galvanized Schedule 40 Pipe (Conveying)
PP-R Fusion Pipe PN16/RDE 7.4 Domestic Use
Welded Schedule 40 Stainless Steel PipeUpdated: July 22, 2026
The dimensions, thicknesses, pressures, temperatures and other characteristics stated in this data sheet are theoretical nominal reference values, compiled from publicly available technical sources: international standards (ASME, ASTM, API, MSS, ISO and NTC, depending on the product) and published engineering literature. They are average approximations intended to guide selection, not a certificate of conformity for any given lot.
Actual values may vary due to conditions inherent to the manufacturing process — dimensional and wall-thickness tolerances (in pipe, typically ±12.5%), surface finish and residual stresses from forming or welding — and to factors inherent to the raw material — chemical composition variations within the ranges allowed by the standard, inclusions or heat-to-heat differences. They may also be affected by in-service events not foreseeable at design time: water hammer, vibration, thermal and mechanical fatigue, corrosion and operating overpressures, which can cause the element to fail before its estimated service life.
To know the certified behavior of a specific lot, TECTUL supplies upon request the manufacturer's mill test certificate (MTC) issued per the product standard; for critical applications, laboratory testing of the lot can also be arranged. In the absence of such certification, the data provided here must not be used as the sole criterion in critical or safety applications, or wherever the integrity of the line may compromise the lives of people or property; in such cases, consult our technical team first.