Control Transformer

Dry-type control transformer to supply control circuits (440/220 to 110 V and combinations). Quoted by VA rating and voltages.

Availability
Quote
Family
Control & automation
Line
Industrial
Response
Same business day
Control Transformer
Product quoted on request

Tell us the reference or key specification (current, power, gauge, size), quantity and city — a technical advisor sends your quote the same business day.

01Technical description

The control transformer is a single-phase dry-type transformer per IEC 61558-2-2 that steps power voltage (440 or 220 V) down to the panel control voltage (110 or 220 V). It is sized in VA by adding coil, pilot light and solenoid loads, with margin for contactor inrush current.

The control transformer is a dry-type transformer used to supply control circuits, coils, pilot lights, relays and control elements inside electrical panels. At TECTUL it is quoted by VA rating, primary voltage, secondary voltage, mounting type and application. The actual lot data includes combinations such as 440/220 to 110 V and other configurations as required. It differs from a control relay and from a timer because it does not execute logic or timing: its function is to adapt and isolate voltage levels for the control circuit. In technical selection, IEC 61558 is a reference for safety of transformers, power supplies and similar equipment; in machinery, IEC 60204-1 guides power supply and protection of control circuits. Selection must consider total load, future growth and suitable protection.

Selection guide

  • Define available primary voltage and required secondary voltage.
  • Add the consumption of coils, relays, pilot lights and control devices.
  • Indicate VA rating if it is already specified on the drawing.
  • Confirm mounting type, available space and panel environment.
  • Validate primary and secondary protections according to the electrical design.

Mounting recommendations

  • Install on plate or compatible rail, with firm mechanical fastening.
  • Protect primary and secondary according to the panel scheme.
  • Maintain sufficient ventilation around the transformer.
  • Identify input and output terminals to avoid crossed connections.
  • Verify secondary voltage before energizing coils and controls.

We dispatch control transformers to Bogotá, Medellín, Cali, Barranquilla and all of Colombia. Request a quote via WhatsApp with voltages and VA rating.

Commercial ratings and thermal classes

ParameterValues
Standard catalog ratings50 · 75 · 100 · 150 · 250 · 500 · 750 · 1000 VA
Usual primaries440 V, 220 V (with combined taps)
Usual secondaries110 V, 220 V
Insulation thermal class (IEC 60085)B = 130 °C · F = 155 °C · H = 180 °C

Control transformers are specified under IEC 61558-2-2 (control and safety transformers). The thermal class per IEC 60085 states the maximum admissible temperature of the insulation system.

02Frequently asked questions

What is the price of a control transformer?

It depends on VA rating, primary and secondary voltages, mounting and availability. TECTUL quotes via WhatsApp with the drawing or required data.

What is the difference between a control transformer and an encapsulated control relay?

The transformer adapts voltage to supply the control circuit. The encapsulated relay switches signals through contacts.

How is a control transformer installed?

It is fixed inside the panel, the primary is connected to the available voltage, the secondary to the control circuit, and both sides are protected according to design.

What data do I need for a quote?

Primary voltage, secondary voltage, VA rating, mounting type and number of loads it will supply.

Can it be 440/220 to 110 V?

Yes. The actual lot data includes dry-type control transformers for combinations such as 440/220 to 110 V and others according to requirement.

Is it suitable for supplying contactor coils?

Yes, as long as the secondary voltage and VA rating are sufficient for the coils and other loads in the control circuit.

How is the control transformer VA calculated?

By adding the sealed (holding) power of all coils, pilot lights and control loads that operate simultaneously, then checking the transformer also rides the inrush of the contactors that close at the same time.

Why not feed the control circuit directly at 440 V?

Because a reduced control voltage (110 V) lowers the risk to operators at pushbuttons and doors, uses standard coils and pilots, and limits damage on a ground fault in the control circuit.