5/8" x 2.4 m Copperweld grounding rod (also 1.2/1.5/1.8 m) with compatible copper connector.

Tell us the reference or key specification (current, power, gauge, size), quantity and city — a technical advisor sends your quote the same business day.
The copperweld rod is a grounding electrode with a steel core clad in at least 254 µm of copper, per UL 467. RETIE requires rod electrodes of at least 2.4 m length, and NTC 2050 (section 250-84) accepts a maximum of 25 Ω per single electrode or requires additional electrodes.
TECTUL's Copperweld rod 5/8" x 2.4 m is an electrode for grounding/earthing systems in industrial, commercial and infrastructure electrical installations. Its function is to provide electrical contact with the soil within the arrangement defined by engineering, either as an individual electrode, part of a grid or complement to a grounding kit. It differs from conductive cement because the rod is the buried metallic element; conductive cement, when applicable, is an electrode-soil contact enhancer. It also differs from the complete kit because this page corresponds to the rod and its compatible connector, not to the assembly with cable, inspection box and enhancer. To quote correctly, indicate length, diameter, quantity, whether you require connector and whether the project needs additional 1.2 m, 1.5 m or 1.8 m rods, lengths mentioned in the lot.
| Actual lot data | Available specification |
|---|---|
| Diameter | 5/8" |
| Main length | 2.4 m |
| Other mentioned lengths | 1.2 m, 1.5 m and 1.8 m |
| Mentioned accessory | Compatible copper connector |
We dispatch to Bogotá, Medellín, Cali, Barranquilla and all of Colombia. Request a quote via WhatsApp for the Copperweld rod 5/8" x 2.4 m indicating quantity, required connector and delivery city.
| Parameter | Value |
|---|---|
| Commercial diameters | 12.7 mm (1/2") and 15.9 mm (5/8") |
| Commercial lengths | 1.2 · 1.5 · 1.8 · 2.4 m (RETIE requires at least 2.4 m as the installation electrode) |
| Copper cladding | Minimum 254 µm (0.254 mm) per UL 467 |
| Target resistance | ≤25 Ω per single electrode (NTC 2050, 250-84) |
The steel core provides the mechanical strength to drive the rod and the copper layer provides conductivity and corrosion resistance. If one electrode exceeds 25 Ω, NTC 2050 requires adding electrodes spaced at least 1.8 m apart.
The price depends on quantity, availability, requested length and whether it is quoted with connector. TECTUL confirms the updated value via WhatsApp.
The rod is only the electrode. The complete kit may include rod, connector, bare copper cable, conductive cement and inspection box according to the design.
It is driven or installed at the point defined by the design, protecting the coating and connecting the conductor with a compatible connector or joint specified by engineering.
The main data is 5/8" x 2.4 m. The lot also mentions 1.2 m, 1.5 m and 1.8 m lengths for quotation according to availability.
The lot description mentions a compatible copper connector, but inclusion must be confirmed when quoting because it may be sold as rod only or with accessory.
Yes. TECTUL dispatches to Bogotá, Medellín, Cali, Barranquilla and other Colombian cities according to availability and transport conditions.
At most 25 Ω per single electrode per NTC 2050 section 250-84; substation and lightning-protection designs target lower values (10 Ω or less) per the project analysis.
Because the steel core withstands driving without bending and the 254 µm copper layer provides the conductivity and corrosion resistance; a solid copper rod of the same diameter costs more and is mechanically weaker.
Updated: July 22, 2026